Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Laboratory Medicine ; (12): 423-430, 2012.
Article in Chinese | WPRIM | ID: wpr-428866

ABSTRACT

Objective To establish and evaluate the new method of 8-color flow cytometry (8c-FCM) with two tube detecting bone marrow minimal residual disease (MRD) in B lineage acute lymphoblastic leukemia (B-ALL).MethodsThe MRD cells were analyzed by using two combinations of 8c-FCM antibody panels,gating with CD19/Side scatter(SSC),CD45/CD10 and CD34(or cTdT).Nalm-6 cell of B-ALL was mixed into normal marrow cells,with proportion of 10.00%,1.00%,0.10%,0.01%and 0.005%,and recovery test and reproducibility test were carried with 8c-FCM established to value its accuracy and precision of.Fluorescence intensity was detected on different time points after marked Nalm-6 by antibodies to evaluate the fluorescent stability of the antibodies.The immunophenotyping was analyzed in 39 bone marrow specimens,including 9 cases of normal control,9 cases of B-ALL primary or recurrent,21 cases of complete remission (CR) after chemotherapy or bone marrow transplantation ( BMT),to evaluate the detection of normal B lymphocyte lineage,leukemia cells of B-ALL,MRD cells of B-ALL using the 8c-FCM and compare it with 4c-FCM in being.ResultsThe method of two tube 8c-FCM with main antibodies of CD19,CD45 and CD10 to detect MRD of B-ALL was founded; CV < 2.5%,average recovery rate was 95.81%,when the actual percent of Nalm-6 mixed into normal bone marrow≥0.10%,and the percent of Nalm-6 detected and actual was linear dependent ( r =0.99,P < 0.05 ) ranged from 10.00% - 0.01 %,when 106 cells were acquired ; the sensitivity of the method established could reach 0.01%.The fluorescent intensity decreased along with the time after Nalm-6 cell marked,but less than 10% in 24 hours.Using the antibody combinations and analyze strategy,the immunophenotye of B lymphocyte in normal bone marrow presented four sequential stages:Stage Ⅰ CD45low/CD10stro/CD20 -/CD38stro/CD34 + or cTdT +,Stage ⅡCD45 +/CD10 + / CD20 -/CD38stro/CD34+ or cTdT +,Stage Ⅲ CD45 +/CD10 +/CD20 -/CD38stro/CD34 -or cTdT-,Stage Ⅳ CD45stro/CD10 -/CD20 +/CD38low/CD34or cTdT.Antigen expressions of leukeamic cells of B-ALL primary or recurrent were different compared with control team; there were 5 cases with MRD positive in CR team,and the main antigen expression was consistent with the results from 4c-FCM.The range of the percent of MRD cells was 0.02% - 5.42% of the 5 cases of MRD positive.ConclusionsThe new method of two tube 8c-FCM established shows good reproducibility and high accuracy,and can identify normal B lymphocyte populations in bone marrow and regenerated B-precursors in CR cases with MRD cells;compared with 4c-FCM,the new method of two tube 8c-FCM with the fewer specimen is faster and efficient to diagnose MRD of B-ALL.

2.
Chinese Journal of Laboratory Medicine ; (12): 395-402, 2011.
Article in Chinese | WPRIM | ID: wpr-417238

ABSTRACT

Objective To explore the values of potential clinical application ofsingle tube/ten colorsflow cytometry for leukocyte differential count in peripheral blood.Methods Utilizing multiple monoclonal antibody combinations and the vavious logical gating strategies,the single tube/12 antibodies with no-wash method for the leukocyte differential count in peripheral blood were determined by using 10 colors flow cytometry.Leukocyte differentials of 142 peripheral blood samples were determined by both Beckman-Coulter LH750 hematology analyzer and 10 colors flow cytometry.The results were then compared to standard microscopic examination as a reference method.The clinical diagnostic efficiency ofsingle tube/10 colorsflow cytometry was calculated.The correlations between standard microscopic cytology,single tube/10 colorsflow cytometry and the hematology analyzer were determined.In addition,the clinical diagnosis efficiency for blast counts ofsingle tube/10 colorswere compared to the results determined by BD FACS Calibur flow cytometer.Results The leukocyte differentials were correlated well between the single tube/10 colorsflow cytometry and standard microscopic cytology(r>0.700,P<0.01) except for basophils.The correlations with neutrophilic granulocytes,lymphocytes,immature granulocytes and blasts were superior(r=0.972,0.951,0.801,0.912,respectively,P<0.01).When 1% was selected as the cut-off point for immature granulocytes determined by standard microscopic cytology,the sensitivity and the specificity ofsingle tube/10 colorsflow cytometry were 92%(57/62) and 79% (63/80),respectively.When 0.5% was selected as the cut-off point for blasts detected by standard microscopic cytology,the sensitivity and the specificity were 99% (67/68) and 92% (68/74).Using the immunophenotyping results from BD FACS Calibur as a standard,the sensitivity for detecting blasts bysingle tube/10 colOrsflow cytometry was 100% (40/40),the specificity was 91% (10/11),the positive predictive value was 98% (40/41),the negative predictive value was 100% (10/10) and the accuracy was 98% (50/51).Conclusions Thesingle tube/10 colorsflow cytometry has a excellent correlation with the standard microscopic cytology when applied on leukocyte differential count in peripheral blood.It may potentially use as a subsequent method for verification of abnormal results of complete blood cell count in the future.

SELECTION OF CITATIONS
SEARCH DETAIL